Air cooled condensing unit and reversible condensing unit ACCU-A - Maxa

Air cooled condensing unit and reversible condensing unit with axial fans and scroll compressors by Maxa

Description


ACCU-A 0104 ÷ 0145 TECHNICAL FEATURES

  • Compressor. Rotary or scroll compressor, complete with overload protection (klixon) embedded in the motor and crankcase, if needed, installed on rubber vibrations absorbing.
  • Fans. Axial fan type low ventilation and special wing profile, they are directly coupled to external rotor motors with protection grade IP54, and a safety fan guard fitted on discharge air flow.
  • Condenser. Copper tubes and aluminium finned coil.
  • Managing system and microprocessor regulation.
  • ACCU-A Version: Refrigerant circuit. The circuit, in copper tubing, includes: manual reset high pressure switch and automatic reset low pressure switch, automatic reset low pressure switch and flare connections with valve or connections to be brazed.
  • ACCU-A/H Version: Refrigerant circuit. The circuit, in copper tubing, includes: 2-ways dryer filter, expansion valve, check valve, 4-ways reverse valve, manual reset high pressure switch, automatic reset low pressure switch, liquid and humidity indicator and flare connections with valve or connections to be brazed.


ACCU-A 0250 ÷ 04185 TECHNICAL FEATURES

  • Compressors. Scroll with oil sight glass. They are fitted with internal overheat protection and crankcase heater if needed, installed on rubber shock absorbers.
  • Fans. Axial fans directly coupled to a three-phase electric motor with external rotor. A safety fan guard is fitted on the air flow discharge.
  • Condenser. Copper tube and aluminium finned coil. The circuits are designed to obtain one or two separate circuits.
  • Managing system and microprocessor regulation.
  • Refrigerant circuit versions ACCU-A and ACCU-A/SSL.
  • Each unit includes independent one or two refrigerant circuits. Produced in copper tubing, all models have high and low pressure switches (with fixed setting).
  • Refrigerant circuit versions ACCU-A/H and ACCU-A/H/SSL.
  • The unit in heat pump version, in addition to the components of  the only cooling unit, includes for each circuit: 4-ways reverse valve, liquid separator on the suction line, liquid receiver, check valves, intermediate exchanger in suction, thermostatic expansion valve with external equalisation, dehydrator filter, level and humidity indicator.

Request information for:

Air cooled condensing unit and reversible condensing unit ACCU-A - Maxa
Accept terms and conditions of Expoclima and data protection and privacy policy of ExpoClima.